Description
Products Name:Product id:–>
Features:1. Display, liquid crystal display (LCD)
2. Maximum display:1999 (3Â 1/2) bits Automatic polarity display
3. Measurement:double integral A / D conversion;
4. Sampling rate:about 3 times per second;
5.Over range display:”0L”
6.Low voltage display:symbol appears;
7.Working environment:(0 ~ 40) ° C, relative humidity
8. Power Battery supply:9V.(battery not included)
9. Volume (size):184 90 46 nm (LWH);10.Weight:about 320g ;
10.Attachment:a manual, a certificate, a box, a pair of pen, K-type thermocouple
Specifications:1.DC voltage(DCV)
Accuracy
Range
2000counts
Resolution
200mV
0.5%+3
0.1mV
2V
0.001V
20V
0.01V
200V
0.1V
1000V
0.8%+10
1V
Input impedance:10MΩOverload protection:200mV range is 550V DC or AC peak;
the rest is 1000V DC or 750V AC peak.
2. AC voltage RMS(ACV)
Accuracy
Range
2000counts
Resolution
200mV
0.8%+5
0.1mV
2V
1mV
20V
10mV
200V
100mV
750V
1.2%+10
1V
Input impedance:10MΩ.Standard sine wave and triangular wave frequency response:40 Hz-1kHz;
other waveform frequency response:40Hz-200Hz
3.DC current
Accuracy
Range
2000counts
Resolution
20uA
0.8%+10
0.1uA
2mA
0.001mA
20mA
2.0%+30
0.01A
200mA
0.1A
10A
1A
The maximum measured pressure drop:200mv Overload protection:200:200mA / 250V speed
Glass Fuse:10A:10A / 250V ceramic speed fuse
4.AC current
Accuracy
Range
2000counts
Resolution
20mA
2.0%+30
0.01A
200mA
0.1A
10A
1A
The maximum measured pressure drop:200mv.Overload protection:200mA:200mA / 250V speed
Glass Fuse:10A:10A / 250V ceramic speed fuse
Frequency response:Sine wave and triangular wave is 40HZ-1KZ; other waveform is 40Hz-200Hz;Display:True RMS;
5.Resistance (Q)
Accuracy
Range
2000counts
Resolution
200Ω
0.8%+5
0.1Ω
2KΩ
0.8%+3
1Ω
20KΩ
10Ω
200KΩ
100Ω
2MΩ
1KΩ
20MΩ
1.0%+25
10KΩ
measurement; Open circuit voltage:less than 3V; overload protection:550V DC or AC peak;
A:In the use of 200Ω range, you should first short-circuit test leads, measured lead
resistance, and then subtracted from the real
B:when measures larger than 1MΩ resistance, the slow reading is a normal phenomenon, please read the value after show stability.
6. NCV measurement;
When the dial to the measurement ncv function, the instrument
approached electric field. beep sound changes according to the strength of the electric beep intermittent sounds also from strong. to weak.
7.Capacitance
Accuracy
Range
2000counts
Resolution
20 nF
3.5%+20
10pF
200nF
100pF
2uF
1nF
20uF
10nF
200uF
5.0%+10
100nF
2mF
1uF
20mF
10uF
Overload protection:550V DC or AC peak
Input sensitivity:1V RMS; overload protection; 550V DC or AC peak (not more than 10 seconds)
>>Please Click Here to Download the English User Manual