Product Description
This dual function product is apt for various domestic, institutional and industrial heating, and cooling applications. It features
- Heating or cooling control
- Red and blue dual led display
- Independent dual-way temperature controller
- Temperature display resolution 0.1
- Direct power output
- Support for high (low) temperature alarm and power loss (the parameters of the sudden power failure are still valid)
- Application in home temperature control, farm, cold storages, greenhouses, aquariums, etc.
Technical Specifications
- Display Type: Digital
- Material: ABS+PCB
- Style: Standing Station
- Temperature sensor: NTC 10K
- Sensor length: 1.0m
- Temperature measuring range: -55 °C ~ 120 °C / -66°F~248°F
- Resolution: 0.1 °C
- Accuracy: ±1° C
- Power supply: 110-220VAC 50/60Hz, 12V DC , 24V DC (Please specify the power supply when ordering)
- Power consumption: <3W
- Storage temperature: -30 °C ~ 75 ° C
- Relative Humidity: 20% ~ 85% (No condensate)
- Relay contact capacity: Two Relay Max 10A, Direct Output
- Dimensions: 7.5*5.5*3.1cm / 2.95*2.16*1.22in
- Weight: 80g / 2.82oz
Operating Instructions
- To set startup temperature: Press the “up” button once to display the starting temperature. Long press the “up” button for about 3 seconds, adjust desired temperature using the up and down keys
- To set the stop temperature: Press the button once to display the stop temperature. Long press the button for about 3 seconds until the stop temperature number begins to flash. Adjust the desired temperature using the up and down keys
- To enter setting mode: Press “Up 1” Button & “Up 2” Button simultaneously
- To return to factory settings, press the “Down 1” and “Down 2” buttons at the same time
- Temperature can be corrected by pressing “Up 1″ and ”Down 1” at the same time for 3 seconds. Positive value = measured value + corrected value (Group 2 temperature correction can be done likewise)
- Heating Mode: Start temperature must be lesser than stop temperature
- Cooling Mode: Start temperature must be greater than stop temperature
Function Codes
Code | Function | Set Range | Default |
P0 | Compressor 1 delay time | 0-60min | 0min |
P1 | Compressor 2 delay time | 0-60min | 0min |
P2 | High temperature alarm value | -55~120°C/-67~248°F | 120°C/248°F |
P3 | Low temperature alarm value | -55~120°C/-67~248°F | -55°C/-67°F |
Packaging Details
- 1 Temperature Controller
- 2 Waterproof Sensors